A phlebotomist reaches for a gold top and finds a red cap with a yellow ring. Same tube type, different manufacturer. At draw stations that mix two brands of blood collection tubes, that moment is where carryover, short draws and rejected specimens start. Tubes are a cheap line on the purchase order and an expensive one to get wrong, because a recollect costs the patient another stick. Buy them as a system: tubes, needles, holders and sets from a list the lab has signed off on.
Blood collection tubes by color and additive
The closure color tells the phlebotomist what is inside. Greiner's VACUETTE instructions for use state that its additives and blood-to-additive ratios follow ISO 6710 and CLSI standards. The core lineup:
- Light blue, sodium citrate 3.2%. Coagulation testing. Greiner specifies 1 part citrate to 9 parts blood.
- Red, clot activator or no additive. Serum.
- Gold, or red with a yellow ring, clot activator with gel. Serum separated by a gel barrier during centrifugation.
- Green, heparin. Lithium heparin plasma for chemistry. Light green on BD tubes and a yellow ring on Greiner tubes means gel.
- Lavender, EDTA. Hematology.
- Gray, sodium fluoride and potassium oxalate. Greiner lists these for glucose and lactate.
Which tube a test needs is not a purchasing decision. Greiner's IFU says the test reagent or instrument manufacturer specifies the additive.
The order of draw and why it prevents carryover
When one venipuncture fills several tubes, the needle can carry a trace of one tube's additive into the next. The order of draw sequences tubes so that trace does the least harm. The Korean Society for Laboratory Medicine's 2025 consensus guideline gives the reason plainly: draw in the specified order to prevent additive carryover.
The sequence printed on BD's June 2023 order of draw guide and on Greiner's U.S. instructions, both based on CLSI GP41:
- Blood culture bottles
- Sodium citrate (light blue)
- Serum, with or without clot activator or gel (red, gold)
- Heparin, with or without gel (green, light green)
- EDTA, with or without gel (lavender)
- Fluoride oxalate (gray)
One update for anyone reprinting wall charts: CLSI published PRE02, Collection of Diagnostic Venous Blood Specimens, on February 13, 2025, replacing GP41 from 2017. Older charts still cite GP41, so ask your lab director whether the facility procedure has been reviewed against PRE02. Both BD and Greiner print the same caution: follow your facility's protocol.
BD Vacutainer and Greiner Vacuette equivalents
Most labs standardize on one brand, then end up with two after a backorder or a contract change. The colors mostly line up. The gel tubes are where staff get caught.
| Draw order | Tube | BD Vacutainer closure | Greiner Vacuette cap and ring | BD inversions |
|---|---|---|---|---|
| 2 | Sodium citrate 3.2% | Light blue | Light blue, black or white ring | 3 to 4 |
| 3 | Serum, clot activator | Red | Red, black or white ring | 5 |
| 3 | Serum with gel | Gold | Red or gold, yellow, gold or white ring | 5 |
| 4 | Lithium heparin with gel | Light green | Green, yellow ring | 8 to 10 |
| 5 | K2EDTA | Lavender | Lavender or pink, black, white or pink ring | 8 to 10 |
| 6 | Fluoride oxalate | Gray | Gray, black or white ring | 8 to 10 |
Teach Greiner's ring code: white means a draw volume of 2 mL or less, black means standard volume, yellow means gel.
Two rules for any station that holds both brands:
- No silent swaps. Greiner's IFU makes it the laboratory's job to verify that a tube change does not significantly affect results. Every equivalent above needs lab sign-off first. See qualifying an alternate SKU.
- Match needles and holders to tubes. Greiner designs its needles, holders and safety devices as a system and leaves cross-brand compatibility to the user.
Draw volumes, pediatric tubes and discard tubes
Fill. Evacuated tubes draw to a set volume, and that volume sets the blood-to-additive ratio. Labcorp instructs that citrate tubes be filled to completion for the 9:1 ratio and never combined when underfilled. A Lab Medicine study notes CLSI H21-A5 recommends citrate tubes be at least 90 percent full. Vacuum is also a storage issue: Greiner specifies 4 to 25°C (40 to 77°F) and warns that exceeding the maximum can cause vacuum loss. A hot supply closet produces short draws.
Pediatric and low-volume tubes. Greiner's white ring flags 2 mL and smaller tubes. Fingersticks and heelsticks run on capillary tubes and lancets such as BD Microtainer, and capillary collection has its own sequence: BD's Microtainer guide starts with lavender K2EDTA. Post that chart separately from the venous one.
Discard tubes. A winged set's tubing is full of air. BD's guide says that when a citrate tube is the first tube drawn through a winged set, a nonadditive or coagulation discard tube must be collected first. Greiner says the same, and VCU Health's pathology guide specifies a 3 mL discard. Any station using butterflies needs discard tubes on the par list.
Needles, holders and safety devices
OSHA bulletin SHIB 03-10-15 states that the bloodborne pathogens standard requires immediate disposal of the entire blood tube holder, needle attached, into a sharps container after the safety feature is activated. It cites EPINet data from 1993 to 2001 attributing about 5 percent of sharps injuries, 1,288 of 25,043, to vacuum blood collection needle and holder sets, and notes that containers with openings too small for the whole assembly do not comply. Our syringes and needles guide covers OSHA's safety device rules.
For the order sheet, that means:
- Single-use holders, forecast from draw volume, or needles with a pre-attached holder such as BD Vacutainer Eclipse.
- Safety winged sets for small or difficult veins: BD Vacutainer Push Button and Safety-Lok, Greiner Vacuette EvoProtect, ICU Medical Saf-T Wing. Keystone carries these in IV and infusion supplies.
- Transfer devices. OSHA says blood drawn by syringe must move to the tube through a needleless transfer device.
- Sharps containers that take the full holder and needle assembly.
The draw station par list
- Every tube on the lab's chart, in the draw volumes the chart specifies, including low-volume tubes if you draw children.
- Discard tubes wherever winged sets are used.
- Needles and single-use holders, or pre-attached units, in your phlebotomists' gauges.
- Safety winged sets in 21, 23 and 25 gauge.
- Tourniquets, alcohol prep, gauze, bandages and sharps containers.
Rotate by expiration date. Our specimen collection checklist covers the rest of the lab.
Quote the whole draw station
Keystone quotes blood collection supplies across 55,000+ SKUs, including BD Vacutainer, BD Microtainer, Greiner Vacuette and ICU Medical, with the manufacturer catalog number on every line so your lab can check it against its validated list. Quotes go out the same day during business hours, and approved accounts get Net 30. Browse laboratory supplies or send your draw station par list for a quote.
Sources
- Greiner Bio-One, VACUETTE Evacuated Blood Collection System Instructions for Use (980200B Rev09, 02-2020): https://www.gbo.com/fileadmin/media/GBO-International/02_Downloads_Preanalytics/TECHNICAL_Instructions_for_Use/English/980200B_09_EN.pdf
- BD, The BD Vacutainer Blood Collection System Order of Draw (June 2023): https://www.testmenu.com/lifespan/TestDirectory/SiteFile?fileName=sidebar%5CBD+Blood+Collection+Tubes+Order+of+Draw++2025.pdf
- BD, Microtainer Tubes with Microgard Closure Tube Guide and Order of Draw: https://www.testmenu.com/UBCHOLab/TestDirectory/SiteFile?fileName=sidebar%5CPAS_BC_Microtainer-tubes-order-of-draw-poster_IM_EN.pdf
- CLSI, PRE02 Collection of Diagnostic Venous Blood Specimens, 8th Edition: https://clsi.org/shop/standards/pre02/
- Chang J, et al., Standards and Practice Guidelines for Venous Blood Collection, Annals of Laboratory Medicine (2025): https://www.annlabmed.org/journal/view.html?uid=3640&vmd=Full
- Labcorp, Blood Specimens: Coagulation: https://www.labcorp.com/resource/blood-specimens-coagulation
- Lab Medicine, Are tube fill volumes below 90% a rejection criterion for all coagulation tests?: https://academic.oup.com/labmed/article/55/4/442/7476684
- OSHA, SHIB 03-10-15, Disposal of Contaminated Needles and Blood Tube Holders Used for Phlebotomy: https://www.osha.gov/sites/default/files/publications/SHIB101503.pdf
- VCU Health Department of Pathology, Order of Draw guide: https://pathology.vcu.edu/media/pathology/catalog/PathologyOrderofDrawGuiderev2.2025.pdf